Extras din referat
I. Chestiuni de studiat
1. Incercarea de functionare in gol
2. Incercarea de functionare in scurtcircuit
3. Separarea pierderilor mecanice si in fier
4. Calculul parametrilor schemei echivalente in T
5. Predeterminarea caract mecanice
6. Schema de montaj
II. Date nominale
Pn= 5 KW
Un=220/380 V/V D/Y
In=21.6/12.5 A/A D/Y
cos 0.7
fn=50 Hz
nn=910 rot/min
U20=177 V
I20=21 A
R1=0.8
III. Tabele cu date masurate
1. Mersul in gol
U10 I10 P10 n cos
I10f P10’ U10f
[V] [A] [W] [rpm] - [A] [W] [V]
410 9.2 1760 995 0.269 9.2 1556.9 236
380 8.4 1680 993.5 0.303 8.4 1510.7 219
350 7.2 1600 994.4 0.366 7.2 1475.6 202
320 6.4 1400 995.7 0.394 6.4 1301.7 184.7
290 5.8 1300 992.2 0.446 5.8 1219.3 167.4
260 5 1200 993.9 0.532 5 1140 150.1
230 4.3 1000 991.9 0.583 4.3 955.6 132.7
200 3.7 800 991.8 0.624 3.7 767.1 115.4
=0.6242, 0.5838, 0.5329, 0.4462, 0.3947, 0.3666, 0.3039, 0.2694
P10’=P10-3R1I10f2 =767.1, 955.6, 1140, 1219.3, 1301.7, 1475.6, 1510.7, 1556.9
2. Incercarea in scurt
U1k I1k P1k I1kf
[V] [A] [W] [A]
60 12.14 730 12.14
IV. Separarea pierderilor
Se calculeaza in tabelul III. 1.
P10’=P10-3*R1I10f2 [W]
P10’=Pm1v+PFe [W ]
PFe=P10’-Pm1v , pt U10=U1n [W]
Din primul grapfic rezulta ca Pm1v este aproximativ 500W, iar din graficul 2 Pm1v este aproximativ egal cu cel din primul grafic, ele nu sunt perfect egale deoarece masuratorile nu sunt facute cu aparate foarte precise, apar erori de masurare si erori de calcul. Deci vom lua Pm1v=500W
Din grafic rezulta ca PFe aproximativ 1100W pentru U10=410V
Preview document
Conținut arhivă zip
- Incercarile de Functionare la Mersul in Gol si Scurtcircuit ale Motorului Asincron Trifazat.doc